DC/DC Converter
TDR 3WI Series, 3 Watt
•
•
•
•
•
Compact design in THD Package
•
•
•
•
•
I/O isolation 1600 VDC
Ultra wide 4:1 input voltage range
Fully regulated outputs
Low ripple and noise
Temperature range –40°C to +85°C
without derating
Continuous short-circuit protection
Remote On/Off control
Fully RoHS compliant
3-year product warranty
UL 62368-1 IEC 62368-1
The TDR 3WI series is a family of compact 3 W DC/DC-converters with 4:1 input voltage ranges and tightly regulated output voltages even under no load
conditions. The product is available in THD-package. They work with high efficiency over the full load range and come with a remote On/Off input. The usability in temperature ranges of up to +85°C, continuous short circuit protection and excellent immunity against environmental influences make these converters very reliable. A TDR 3WI converter is the ideal solution for space critical
high end applications in communication equipment, instrumentation and industrial electronics.
Models
Order Code
Input Voltage
Range
TDR 3-1211WI
TDR 3-1212WI
TDR 3-1213WI
TDR 3-1222WI
TDR 3-1223WI
TDR 3-2411WI
TDR 3-2412WI
TDR 3-2413WI
TDR 3-2422WI
TDR 3-2423WI
TDR 3-4811WI
TDR 3-4812WI
TDR 3-4813WI
TDR 3-4822WI
TDR 3-4823WI
www.tracopower.com
4.5 - 18 VDC
(12 VDC nom.)
9 - 36 VDC
(24 VDC nom.)
18 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
5 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
5 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
5 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
600 mA
250 mA
200 mA
125 mA
100 mA
600 mA
250 mA
200 mA
125 mA
100 mA
600 mA
250 mA
200 mA
125 mA
100 mA
November 14, 2023
Vnom
Efficiency
Imax
–12 VDC
–15 VDC
125 mA
100 mA
–12 VDC
–15 VDC
125 mA
100 mA
–12 VDC
–15 VDC
125 mA
100 mA
typ.
81 %
82 %
82 %
82 %
81 %
80 %
82 %
82 %
82 %
81 %
80 %
83 %
82 %
82 %
81 %
Page 1 / 4
TDR 3WI Series, 3 Watt
Input Specifications
Input Current
- At no load
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
- At full load
Surge Voltage
Reflected Ripple Current
Recommended Input Fuse
Input Filter
40 mA typ.
20 mA typ.
13 mA typ.
330 mA max.
165 mA max.
80 mA max.
25 VDC max. (1 s max.)
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
80 mAp-p typ.
40 mAp-p typ.
30 mAp-p typ.
2'500 mA (slow blow)
1'500 mA (slow blow)
1'000 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Capacitor
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
Capacitive Load
- Cross Regulation
(25% / 100% asym. load)
- 20 MHz Bandwidth
- single output
- dual output
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Transient Response
±1% max.
0.2% max.
0.2% max.
1% max.
1% max. (Output 1)
1% max. (Output 2)
dual output models: 5% max.
single output models:
dual output models:
single output models:
dual output models:
5 Vout models:
12 Vout models:
15 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
- Response Time
30 mVp-p typ.
1'680 µF max.
820 µF max.
680 µF max.
470 / 470 µF max.
330 / 330 µF max.
Not required
±0.02 %/K max.
5 ms typ.
Continuous, Automatic recovery
250 µs typ. (25% Load Step)
Safety Specifications
Standards
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/tdr3wi
PD 2
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 14, 2023
Page 2 / 4
TDR 3WI Series, 3 Watt
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
EMS Immunity
External filter proposal:
Air:
Contact:
- Electrostatic Discharge
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
1 s:
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
www.tracopower.com/overview/tdr3wi
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
220 µF / 100 V
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
Cooling System
Remote Control
Altitude During Operation
Regulator Topology
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
Environment
Housing Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
95% max. (non condensing)
–40°C to +85°C
+100°C max.
–55°C to +125°C
3.3 %/K above 70°C
See application note: www.tracopower.com/overview/tdr3wi
Natural convection (20 LFM)
On: open circuit
- Current Controlled Remote
Off: 2 to 4 mA current (internal 1 kΩ resistor)
(passive = on)
Refers to 'Remote' and '-Vin' Pin
External circuit proposal: www.tracopower.com/info/current-remote.pdf
2.5 mA max.
- Off Idle Input Current
5'000 m max.
Flyback Converter
100 kHz min. (RCC)
Basic Insulation
1'600 VDC
- Input to Output, 60 s
1'000 MΩ min.
- Input to Output, 500 VDC
50 pF max.
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
5'700'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
MIL-STD-810F
- Vibration
MIL-STD-810F
- Thermal Shock
Non-conductive Plastic (UL 94 V-0 rated)
Epoxy (UL 94 V-0 rated)
Copper
Nickel (40 - 120 µm)
Gold (25 - 75 nm), matte
Overmold
PCB Mount
THD (Through-Hole Device)
DIP14
Lead-Free Wave Soldering
265°C / 10 s max.
4.5 g
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 14, 2023
Page 3 / 4
TDR 3WI Series, 3 Watt
Environmental Compliance - REACH Declaration
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
a5705e01-1df1-406a-b8db-a2eede0d9d3f
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tdr3wi
Outline Dimensions
Pinout
Dimensions in mm (inch)
Tolerances: ±0.5 (±0.02)
Pin pitch tolerances ±0.25 (±0.01)
0.25 (0.01)
13.55 (0.533)
0-15°
(0.1)
Single
Dual
1
–Vin (GND)
–Vin (GND)
2
Remote On/Off
Remote On/Off
6
NC
Common
7
NC
–Vout
8
+Vout
+Vout
9
–Vout
Common
14
+Vin (Vcc)
+Vin (Vcc)
NC: Not connected
8
7
9
6
18.9 (0.74)
2.54
(0.4)
1.8 2.54
10.16
12.8 (0.50)
(0.07) (0.1)
(0.15)
1.3 (0.05)
3.8
0.8 (0.03)
8.7(0.35)
Pin
top view
2
14
1
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. November 14, 2023
Page 4 / 4
很抱歉,暂时无法提供与“TDR 3-2412WI”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+310.685891+38.54044
- 10+270.7750810+33.58953
- 25+261.8378625+32.48087
- 50+255.2731550+31.66652
- 100+248.87201100+30.87246
- 250+240.65480250+29.85312
- 500+214.22754500+26.57483